1.2.two Warning Labels Warning Labels Indicating Make sure you carefully read through this handbook in advance of use gadget. The subsequent labels can be a. Usually do not area the unit with a sloped surface. Normally the obtainable once the system system may slide, leading to private harm or the system works While using the cellular malfunction.

The consumer will not be allowed to open up the covers and panel of the method, neither Notice: product disassemble is allowed. To make sure the technique functionality and security, only Mindray engineers or engineers authorized by Mindray can accomplish maintenance.

Get a complete and extended look at on the anatomical framework as a result of panoramic imaging coupled with velocity indication and forward/backward scan potential creating scanning much simpler, smoother and a lot more controllable.

This manual could referring to info protected by copyright or patents and won't convey any license underneath the patent rights or copyright of Mindray, or of Other people. Site 9: Assertion

Lower off cable ties connecting the leading unit around the Screen by diagonal cutting pliers, and then pull out the corresponding cable plugs.

Mindray’s new technology of black & white ultrasound technique, DP-fifty Expert, is equipped with Innovative imaging systems letting further penetration and more quickly impression acquisition with larger resolution.

S. must present the Office by having an electronic mail address if they've a single. The emails supplied may be utilized for Formal conversation With all the licensee. Even so email addresses are general public document. If you don't wish to produce a private handle, you should supply the Office with the email tackle which may be manufactured accessible to the general public. Make sure you see our Chapter 455 web site to determine When you are impacted by this modification.

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi depth mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

iZoom™ allows correct viewing of picture from distance iWorks™ Protocol aids standardize workflow and lessen Examination moments

Perform: Around the again-conclusion of the most crucial board, a Distinctive observe IC is made use of to watch sign voltages  and clock battery ability which might be offered to the primary board by the main unit box power offer module.

Soon after effective connection, the recently extra community printer name might be shown while in the printer driver record. Observe: Before hook up the community printer, ensure that the ultrasound method plus the printer are in the exact same community domain, plus the network is Functioning Generally. The IP address plus the server name really should be valid, e.g. Page 47 DICOM Setting  Enter the AE Title from the ultrasound technique, port and PDU based on the true situation, and then simply click [OK] to exit the display screen.

.. Website page 161 The indicator to the printer Errors manifest in the event the adapter turns orange, plus the printing printer adapter runs. Disconnect and hook up the fails. power adapter, electrical power on the printer adapter yet again, and confirm whether the printing is typical soon after one minute. Website page 163: Electrical Security Inspection

Overall performance Test 5.5.one Test Procedure Resolution Detection depth Geometric Situation Precision Blackout area test History the exam images five.five.2 Take a look at Content The image used Here's only for reference, stick with the graphic effect in the actual NOTE: condition. Needs: Screen: established the contrast and brightness for the medical software worth (or even the default position) Operation natural environment: dark space, simulating the medical software environment. Website page 76 In affliction which the transverse resolution testing targets are horizontally displayed, file the nominal distance of two targets which might be clearly recognized. Repeat the operation over to the transverse resolution tests targets at other depths. As revealed in figure down below. Axial resolution ... Page seventy seven When utilizing the convex probe, maintain the transverse resolution tests targets to notice: be exhibited close to the midline. When employing a linear probe with steer functionality, tend not to turn on the steer functionality when perform the transverse resolution test. Zoom inside the area in which the targets Situated if required. The diameter of your concentrate on place at a particular depth is equal towards the transverse resolution for the depth. Web site seventy eight five.

Right after replacing the CPU module, essential file needs to be created Again according to the new MAC address and composed Dp50rb login into HDD from the equipment. Or else, the configuration functionality of the item will likely be lost. Right after eliminating the CPU module, Get rid of panhead screws with washers (twelve M3X6) fixed on the primary unit box, you usually takes off the board. Page 118 Determine eight-29 Disassemble the User interface Assembly (1) Hold the higher edge of user interface assembly, and open up up the control panel. Determine 8-thirty Disassemble the Control Panel Assembly (2) Soon after eliminating a person countersunk head self-tapping screw PT3X10 mounted about the control panel and take out the plug of your keyboard and the key device connecting cables, you could clear away the control panel assembly.

NOTE: Be certain that you may pull out and press into the IO board sockets vertically when pulling out and assembling the IO board assembly within the situation from the take care of. Take out panhead screws with washers M3X6 (4) used to secure the IO board, and afterwards you could potentially get out the IO board. Website page 116 Take away panhead screws with washers (two M3X6) which might be mounted on the primary device, acquire out the upper baffle and afterwards pull out two cables connecting the leading board to the ability module assembly.